Page 22 - PLC Automation
P. 22
20 MAIN CATALOG PLC AUTOMATION
01
—
PLC Automation product family
AC500 CPU Selector
Your requirements Application specification and
performance needs
You are looking for a well established PLC solution with large product range for all kind of Cost-effective application Small application Medium to large application Large demanding application Extremely demanding
applications. You need particularly: • with compact PLC and a small number of I/Os • less-complex communication via • good motion capability • with fast response time for motion, application
• Support of CS31 serial interface communication and standard industrial fieldbus • medium to complex communica- calculation or complex communica- • complex communication with
High Availabilty solution with fast switching time • simple safety solution tion via standard industrial field- tion via standard industrial field- embedded Ethernet based
• Condition Monitoring capability bus and Ethernet based protocols bus and Ethernet based protocols coupler and fast response time
• Support of various types of communication protocols like • safety applications with F-Device • complex safety calculation with • highly-complex safety support
PROFIBUS DP, CANopen, PROFINET, EtherCAT or serial interface protocols support F-Device support and/or CMS with F-Device
• IoT connection with MQTT support • high speed and/or extensive
• Safety applications with support of PROFIsafe communication (F-Host and F-Device) coordinated motion control
• PLC integration into System 800xA DCS communication
AC500-eCo AC500
What does your project need? PM5x4 PM5x6 PM57x PM58x PM585-ETH PM59x-ETH PM591-2ETH PM592-ETH PM595-4ETH
Compactness and onboard I/Os ?
Basic 230 V AC power supply onboard ?
Standard operational temperature ?
Extreme environmental conditions (e.g. high temperature, humidity or vibrations) ? - - (XC) (XC) - (XC) (XC) (XC) (XC)
Functional Safety up to SIL3 ?
/ -
/ -
/ -
/ -
/ -
/ -
/ -
/ -
/ -
Simple motion with PTO module FM562 / onboard I/O ?
Application feature Data logging ? - - - - - - - - - -
High-speed motion or interpolated motion ?
-
-
-
-
-
-
-
-
-
Condition monitoring CMS ?
High availability with CS31 protocol ?
High availability with Ethernet Modbus TCP protocol ?
HTML5 web server ?
Telecontrol with IEC 60870-5-104 ?
Process control objects library (PCO) for DCS integration ? - - - - - - - - -
Application performance More than 1 Cyclic and 1 Interrupt IEC 61131 Task ? - 128 KB / 14 KB - 512 KB / 130 KB
-
4 or more IEC 61131 Tasks ?
-
-
More than 2 kB retain variables ?
2-4 MB / 2-4MB
1 MB / 2 MB
1 MB / 1 MB
16 MB / 16 MB
512 KB / 512 KB
4 MB / 4 MB
User program / User data memory ?
4 MB / 4 MB
Large flash disk for data collecting ?
4 GB
-
-
-
4 GB
Web server data ≤ 1MB ?
-
-
8 MB
8 MB
8 MB
-
16 MB
4 MB
4 MB
Web server data ≥ 4MB ?
Floating point arithmetic calculation with FPU ?
-
-
-
-
Number of Ethernet Sockets for parallel connection ?
≤ 12
≤ 12
≤ 12
Number of Modbus TCP Sockets (part of Ethernet Sockets) ?
≤ 12
≤ 12
≤ 12
≤ 28
≤ 28
≤ 12
2 ns
0.6 ns
60 ns
2 ns
CPU performance (ns per bit instruction) ? ≤ 13 ≤ 13 ≤ 13 ≤ 22 ≤ 29 ≤ 29 ≤ 61 ≤ 29 ≤ 61
80 ns
80 ns
2 ns
50 ns
4 ns
Decentralized I/Os or communication on serial CS31 fieldbus ?
Decentralized I/Os or communication on serial Modbus RTU fieldbus ?
-
Decentralized I/Os or communication on PROFIBUS DP master / slave fieldbus ?
/
/
/
/
-
/
/
/
Communication/Fieldbus Decentralized I/Os or communication on Modbus TCP network ?
-
Decentralized I/Os or communication on CAN/CANopen master / slave fieldbus ?
-
/
/
/
/
/
/
/
Decentralized I/Os or communication on PROFINET IO controller / device network ?
-
-
/
/
/
/
/
/
/
-
Decentralized I/Os or communication on EtherCAT master network ?
-
-
-
-
-
-
Two or more onboard Ethernet interfaces ?
-
-
/ / -
-
-
-
-
Onboard selectable protocols PROFINET IO / EtherCAT ?
-
-
-
-
-
-
-
-
-
-
-
-
KNX building communication
-
BACnet (B-ASC profile) / BACnet (B-C profile)
-
-
-
-
IEC 61850 MMS / GOOSE protocol ?
-
-
-
-
IoT enabled with MQTT with TLS secured communication, support of JSON library - - - / - / - / - / - / - / - / - / -
OPC UA server ? - - - - - - - - -
- Not possible
Possible but not optimal solution
Possible with additional devices
Possible and best selection