Page 48 - Railway Applications_Terminal blocks
P. 48
ZK2.5-SF PI-Spring terminal blocks
For 5x20 fuses - 6 mm 0.236 in spacing
2.5 mm² Description
12 AWG
Protect your circuits with 5x20 fuse terminal blocks compliant with IEC 60947-7-3 standard (fuse not sup-
2 plied with the terminal blocks),
ZK2.5-SF –– Simplify the distribution thanks to the 2 jumper channels aligned with ZK4-3P feed-through and ZK2.5-S-R1
disconnect terminal blocks.
63.1 2.48"
Ordering details Color Type Order code Pkg Weight
24.6 0.97" Grey, dark grey ZK2.5-SF 1SNK706410R0000 qty (1 pce) g
Description 50 16.20
6 mm 0.236 in spacing
12 1SNK162090V0014 Fuse Mounting instructions
34
56 Main technical data IEC UL - CSA Rail TH 35-7.5,
78 TH 35-15
Connecting capacity
1 conductor Rigid - Solid / Stranded 0.2 ... 4 mm² 26 ... 12 AWG Wire stripping 11 mm
per clamp Flexible 0.22 ... 2.5 mm² length 0.433 in
with non insulated ferrule 0.22 ... 2.5 mm² 26 ... 14 AWG
with insulated ferrule 0.22 ... 2.5 mm² 26 ... 14 AWG
2 conductors with twin ferrule 0.22 ... 0.5 mm² 26 ... 20 AWG Tool (for flexible Flat screwdriver
per clamp conductor without Ø 3.5 mm
ferrule)
Ø 0.138 in
Rated current / Rated cross section 6.3 A / 2.5 mm² 16 A / 12 AWG
Rated short-time withstand current (1s) 396 A
Rated voltage 500 V 300 V
Impulse withstand voltage 6000 V NEMA 1
Protection IP20
81.5 3.21" The fuse holder must be first disconnected prior any fuse replacement. Mount your fuse safely without touching
74 2.91" any active part: put the fuse into the hooks of the fuse holder shutter; at the closing of the shutter, the fuse is
perfectly in place in the fuse holder.
Separate Assembly composed of 1 fuse terminal block in Overload and short-circuit 2.5 W
arrangement between non fuse terminal blocks protection
Exclusive short-circuit protection 4 W
Compound Assembly composed of 5 fuse terminal blocks Overload and short-circuit 1.6 W
arrangement protection
Exclusive short-circuit protection 4 W
The connecting capacity data for one Rigid - Solid / Stranded - Flexible conductor (when applicable) is a mandatory information required by IEC, UL and CSA standards (Copper conductors).
All other data are provided as supplementary information only. For more details, please consult our CB, UL or CSA certificates and technical datasheet available on http://www.ABB.com
CE CB RoHS USR CNR CSA EAC BV DNV
Accessories
Description Color Type Order code Pkg Weight
1 End stops 5.2 mm 0.205 in Dark grey BAZ1 1SNK900002R0000 qty (1 pce) g
Dark grey
2 End sections 2 mm 0.079 in EK2.5-3P 1SNK705911R0000 50 5.30
Orange 20 2.40
3 Jumper bars 2 poles 41 A (IEC) JB6-2 1SNK906302R0000 50 1.30
Dark grey 50 2.10
3 poles 41 A (IEC) Dark grey JB6-3 1SNK906303R0000 50 2.90
Dark grey 50 3.60
4 poles 41 A (IEC) Dark grey JB6-4 1SNK906304R0000 20 7.40
10 38.10
5 poles 41 A (IEC) White JB6-5 1SNK906305R0000 20 6.40
20 1.70
10 poles 41 A (IEC) JB6-10 1SNK906310R0000 20 2.40
10 5.20
50 poles 41 A (IEC) JB6-50 1SNK906350R0000 10 0.80
1680 0.27
4 Circuit separators 3 mm 0.118 in CS-R3 1SNK900107R0000 22 10.00
20 11.00
5 Test adapters For test plugs DIA 2 mm 0.079 in TP2 1SNK900203R0000
For test plugs DIA 4 mm 0.157 in TP4 1SNK900205R0000
6 Test connectors End module, 5.2 mm 0.205 in TC5-R1 1SNK900201R0000
7 Spacers 0.8 mm 0.031 in ES-TC6 1SNK900105R0000
8 Terminal block Blank marker MG-CPM-13 41791 1SNB041791R0612 1SNK162021S0201 - Rev. B
markers
Blank card MC612 1SNK150000R0000
MC612PA 1SNK159999R0000
Complete list of accessories is indicated in the terminal block datasheet including end stops.
Some accessories such as jumper bars may modify the terminal block's ratings: Complete information available in the accessories section of the catalog.
All the technical data for UL/CSA standard and dimensions in inches are in italic.
Technical data valid for copper conductors only.
46 | ABB Railway applications – Terminal blocks