Page 57 - 1SNC160020C0201_Solution series
P. 57




D1.5/8.SF.ADO IDC terminal blocks
For 5 x 20 and 5 x 25 fuses - with blown fuse indicator and test

socket ADO - ADO - 8 mm 0.315 in spacing



1.5 mm² Description
The ABB ADO System fuse holders provide circuit protection for control applications,
®
16 AWG Quickly identify the defective circuit thanks to blown fuse indicators,
With the ABB ADO System , experience the fastest and most reliable connection on the market,
®
2 Designed for control applications exposed to severe constrains (vibrations, shocks, corrosion etc.),
Up to 2 wires per connection.
Ordering details
1SNC163092F0014 Description Color Type Order code Pkg Weight
(1 pce) g
pce
With blown fuse indicator by
Fuse
neon 110 - 230 V and 2 test sockets Grey D1.5/8.SFLT.ADO 1SNA199211R2300 50 14.00
With blown fuse indicator by Grey D1.5/8.SFDT.ADO 1SNA199212R2400 50 14.00
LED 24 V DC and 2 test sockets
D1.5/8.SF.ADO
Main technical data Mounting instructions
IEC UL CSA Rail TH 35-7.5,
TH 35-15
ADO Rigid - Solid / Stranded 0.34-1.5 mm² 22-16 AWG 22-16 AWG Wire stripping
80.5 3.17" Flexible 0.34-1.5 mm² length
Screw clamp Rigid - Solid / Stranded Tool
98 3.86" 90.5 3.56" Flexible
with insulated ferrule
56 2.20" 49 1.93" Rated current / Rated cross section 6.3 A / 1.5 mm² 8 A / 16 AWG 10 A / 16 AWG
Gauge
Rated short-time withstand current (1s) 180 A Torque
Rated voltage 500 V 600 V 600 V
43 1.69" Impulse withstand voltage 6000 V
Protection IP20 NEMA 1
The connecting capacity data for one Rigid - Solid / Stranded - Flexible conductor (when applicable) is a mandatory information required by IEC, UL and CSA standards.
8 mm 0.315 in spacing All other data are provided as supplementary information only. For more details, please consult our CB, UL or CSA certifcates and technical datasheet available on http://www.ABB.com
CUS
RoHS USR cCSAus Gost R





Accessories
Description Color Type Order code Pkg Weight
pce (1 pce) g
1 2
1 End stops 10 mm 0.394 in Grey BAM2 1SNA206351R1600 50 12.00
9 mm 0.354 in BADL 1SNA399903R0200 50 4.70
2 End sections 1.5 mm 0.059 in Grey FEDAD7 1SNA199382R2700 20 3.80
3 Test plugs DIA 2 mm 0.079 in Black FC2.MC 1SNA107239R0300 20 1.00
3 4 4 Fuses 0.5 A FU520 1SNA008288R1500 10
1 A 1SNA008290R1300 10
2 A 1SNA008291R0000 10
3.15 A 1SNA008289R1600 10
5 A 1SNA008292R0100 10
5 6
5 Assembly rods 2 poles TGA8 1SNA168672R1100 10 1.00
3 poles 1SNA168673R1200 10
4 poles 1SNA168674R1300 10
6 Spring retaining rings ANT 1SNA168675R1400 10
7 8 7 Tools Semi automatic tool OUPAD 1SNA178944R0400 1 205.00
Hand tool OUMAD 1SNA179466R0600 1 29.00
8 Terminal block markers Blank card White RC810 1SNA234000R0200 1 8.20
Complete list of accessories is indicated in the terminal block datasheet.
Some accessories such as jumper bars may modify the terminal blocks ratings: complete information in the accessories catalogue pages.




Disconnect IDC terminal blocks 1SNC163057S0201 - Rev. A
Description Color Type Order code Pkg Weight
pce (1 pce) g
Disconnect Profle aligned with D1.5/8.SF.ADO Grey, blue D1.5/8.SNNT.ADO 1SNA199210R0600 50 17.00
All the technical data for UL/CSA standard and dimensions in inches are in italic.
Technical data valid for copper conductors only.
54 | ABB Solution series - Terminal blocks
   52   53   54   55   56   57   58   59   60   61   62