Page 225 - Motor protection and control Manual motor starters, contactors and overload relays
P. 225
AF09Z...38Z-..-..-30, NFZ22E-30...NFZ80E-30, CA4, CAL4, LDC4
1SBC101053M6801 - 01/18 3/151
ABB MOTOR PROTECTION AND CONTROL
Contactors AF..Z-...-30, contactor relays NFZ...-30 and accessories Operating instructions
—
Schütze AF..Z-...-30, Hilfsschütze NFZ...-30 und Zubehör Betriebsanleitung
AF09Z ... AF16Z 4-pole contactors
Contacteurs AF..Z-...-30, contacteurs auxiliaires NFZ...-30 et accessoires Notice d'instruction
Kontaktorer AF..Z-...-30, reläkontaktorer NFZ...-30 och tillbehör Instruktion
25 to 30 A AC-1
Contattori AF..Z-...-30, contattori ausiliari NFZ...-30 e accessori Istruzioni tecniche
24 V DC operated designed for PLC
Contactores AF..Z-...-30, contactores auxiliares NFZ...-30 y accesorios Instrucciones de empleo
AF..Z-...-30, NFZ...-30
Z-...-30, NFZ...-30,
AF09Z ... AF16Z 4-pole contactors are mainly used for controlling non-inductive or slightly inductive 03
loads (i.e. resistance furnaces...) and generally for controlling power circuits up to 690 V AC and
440 V DC. These contactors are of the block type design with 4 main poles. Uc
A1
• control circuit: 24 V DC operated with electronic coil interface allowing low holding consumption A2
1SBC101529V0014 up to 1.7 W and reduced panel energy consumption
- allow direct control by PLC-output ≥ 250 mA 24 V DC
AF09Z...16Z-30-01-30 - very distinct closing and opening
AF09Z...16Z-30-22-30
AF26Z...38Z-30-22-30
AF09Z...16Z-30-10-30 AF26Z...38Z-30-00-30 • built-in surge suppression AF26Z...38Z-30-11 NFZ...-30,
NFZ44E...80E-30
AF09Z...38Z-..-30
AF09Z-40-00
AF09Z..16Z-40-00-30 • add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
AF09Z..16Z-22-00-30
NFZ22E ...40E-30
IEC UL/CSA Rated control circuit Auxiliary Type Order code Weight
CAL4-11 1
Rated operational General use voltage contacts
current rating Uc fitted Pkg
CA4 -10 θ ≤ 40 °C 600 V AC (1 pce)
-01
AC-1
A A V DC kg
4 N.O. main poles CAL4-11 2 A1 Uc A2
CAL4-11 25 25 24 0 0 AF09Z-40-00-30 1SBL136201R3000 0.430
30
CA4-40/22/31/04 30 24 0 0 AF16Z-40-00-30 1SBL176201R3000 NFZ...-30, 0.430
3
AF09Z...38Z-..-30
TF42 2 N.O. + 2 N.C. main poles
AF09Z ... 38Z-..-..-30 TF42 AF09Z...38Z TF42 AF26Z...38Z 4
25 25 24 0 0 AF09Z-22-00-30 1SBL136501R3000 0.430
NFZ40E-30 NFZ40E-30
AF16Z-22-00-30 1SBL176501R3000
0 0
Pos. 2 AF09Z...16Z-30-10-30 30 +30° 30 -30° 24 AF09Z...16Z-30-10-30 + max 4 aux contacts / 3NC 0.430
AF09Z...16Z-40-00-30 + max 4 aux contacts / 4NC AF09Z...16Z-40-00-30 CA4-04
AF26Z...38Z-30-00-30
AF26Z...38Z-30-00-30 Note: AF..Z contactors with 24 V DC control voltage need to respect the connection polarities indicated close to the coil terminals:
CLIC !
A1+ for the positive pole and A2- for the negative pole.
AF09Z...16Z-30-01-30 + max 4 aux contacts / 3NC NFZ31E-30, NFZ22E-30 + max 4 aux contacts / 2NC
Pos. 4
AF09Z...16Z-22-00-30 CA4-04 AF09Z...16Z-30-01-30 CA4-04
Pos. 3 NFZ31E-30, NFZ22E-30 AF09Z...16Z-22-00-30 NFZ...-30, AF09Z...38Z-..-30 + LDC4
Pos. 1 Pos. 1 ± 30° Pos. 5
AF26Z...38Z-30-11-30 + max 1 x CAL4-11 AF26Z...38Z-30-11-30 + max 1 x CAL4-11 A1 A2
A1 + Uc= 24VDC According to UL60947-4-1 and CSA C22.2 NO. 60947-4-1, for use on a circuit capable of delivering not
more than the max. symmetrical amperes at the max. voltage shown in the table below.
AF09Z...38Z-..-30 WARNING : if opening of BCP, controller shall be examined and replaced if damaged.
- NFZ...-30
A2 AF09, AF12 AF16 Max Short- AF26 AF30 AF38 Uc
Max Short- max Fuse max Fuse circuit at max Fuse max Fuse max Fuse 1
circuit at 480V, 600V 60A/RK5 60A/J 100A/RK5 100A/J 100A/RK5 100A/J
480V, 600V 30A/RK5 30A/J 60A/RK5 60A/J (kA) 5 100 5 100 5 100
(kA) 5 100 5 100 AF26/AF30/AF38 AF26/AF30/AF38 AF26/AF30/AF38
AF09/12/16 Max Short- Circuit Breaker LDC4 A1 A2
Max Short- Circuit Breaker Circuit Breaker
circuit at Circuit-Breaker circuit at T4V250 + TM250 XT1H125 + TM100 XT2V125 + TM100
480V, 600V XT2V125 + TM60 480V (kA) 35 65 65 2
(kA) 10 600V (kA) 25 - 42
H
CLIC !
L
mm² mm² mm² mm L mm L mm Assembly - Anbau - Montage - Montering
AF09Z...16Z-...-30 M 3,5 2 x 2 x 2 x 0,75...2,5 L = 10 L < 9,6 _ Montaggio - Montaje - -
3 & 4-pole 1,5 N.m Ø 5,5 1...6 0,75...6 1 x 0,75...4
AF26Z...38Z-...-30 M 4 2 x 2 x 2 x 1,5...4 _ 35 mm
3-pole 2,5 N.m Ø 6,5 2,5...10 1,5...10 1 x 1,5...10 L = 14 L < 12,5 EN/IEC 60715
AF09Z...16Z-30-10-30 pozidriv N° 2 _
AF09Z...16Z-30-01-30 M 3,5 2 x 2 x 2 x 0,75...1,5 L = 10 L < 9,6
NFZ...-30 1,2 N.m Ø 5,5 1...2,5 0,75...2,5 1 x 0,75... 2,5 2
AF09Z... 38Z-30-22-30 L < 8 _
AF26Z... 38Z-30-11-30 Disassembly - Abbau
AF09Z ... 38Z-...-30 M 3,5 Ø 5,5 2 x 2 x 2 x 0,75....1,5 L = 10 L < 8 _ Démontage - Demontering
NFZ...-30 1,2 N.m 1...2,5 0,75...2,5 1 x 0,75... 2,5 Smontaggio - Desmontaje 2
-
A B A B
mm inch
mm inch mm inch NFZ44E...NFZ80E-30 130,5 5.14" mm inch Acc. to UL60947-4-1 and
NFZ22E...NFZ40E-30
91 3.58"
97 3.82"
91 3.58"
CSA C22.2 NO. 60947-4-1, min. enclosure for :
6 0.24" Main dimensions mm, inches AF09Z...16Z-30-22-30 139,5 5.49" 100 3.94" AF09Z...AF16Z-...-30, NFZ...-30, : 180 x 130 x 175 mm
AF09Z...16Z-...-30
AF09Z...38Z-...-30,
AF26Z...38Z-30-22-30
AF26Z...38Z-...-30 3-pole
106 4.17" 100 3.94"
NFZ22E...NFZ80E-30
AF26Z...38Z-30-...-30 3-pole : 255 x 180 x 175 mm
131,5 5.18"
100 3.94"
AF26Z...38Z-30-11-30
97 3.82"
130.5 5.14"
35 1.38"
2 x
97 3.82" 35 1.38" 91 3.58" ø 4.2 0.17" M4 8-32 UNC
91 3.58"
45 1.77" 5.5 0.22" 5.5 0.22" 2 x
91 3.58"
ø 4.2 0.17"
5.5 0.22" M4 8-32 UNC
80 3.15" 6 0.24"
80 3.15" 35mm EN/EC 60715 35 mm EN/IEC 60715 5.5 0.22" 60 2.36" 35mm EN/EC 60715 5.5 0.22" 70 2.76" 43 1.69" 60 2.36" 70 2.76"
5.5 0.22"
2 0.08" 2 0.08" 10 0.39" 5 0.20" 5 0.20"
45 1,77" 10 0.39" 5 0.20" 10 0.39"
5 0.20" 1SBC100329S0201 - Rev. A
ABB France AF09Z, AF16Z
3, rue Jean Perrin
69680 Chassieu / France
www.abb.com/lowvoltage