 AC / DC Control supply  Type  AF09  AF12  AF16  AF26  AF30  AF38  AF40  AF52  AF65  AF80  AF96  AF116  AF140  AF146 AF190  AF205  AF265 AF305 AF370 AF400  AF460  AF580  AF750  AF1250 AF1350  AF1650  AF2050 AF2650
 IEC  AC-3 Rated operational power  220 - 230 - 240 V  kW  2.2  3  4  6.5  9  11  11  15  18.5  22  25  30  37  45  55  55  75  90  110  110  132  160  220  —  257  315  —  —
 θ ≤ 60 °C for AF09 ... AF370  380 - 400 V  kW  4  5.5  7.5  11  15  18.5  18.5  22  30  37  45  55  75  75  90  110  132  160  200  200  250  315  400  —  475  560  —  —
 θ ≤ 55 °C for AF400 ... AF2650  415 V  kW  4  5.5  9  11  15  18.5  22  30  37  45  55  55  75  75  90  110  132  160  200  220  250  355  425  —  500  630  —  —
 440 V  kW  4  5.5  9  15  18.5  22  22  30  37  45  55  75  90  90  110  132  160  160  200  220  250  355  450  —  560  710  —  —
 500 V   kW  5.5   7.5  9  15  18.5  22  22  30  37  45  55  75  90  90  110  132  160  200  250  250  315  400  520  —  560  710  —  —
 690 V  kW  5.5   7.5  9  15  18.5  22  22  30  37  45  55  55  75  90  132  160  200  250  315  315  355  500  600  —  800  1000  —  —  5
 1000 V  kW  —  —  —  —  —  —  —  —  —  35  40  —  —  75  110  132  132  132  132  220  280  355  400  —  —  —  —  —
 Rated operational current  380 - 400 V   A  9  12  18  26  32  38  40  53  65  80  96  116  140  146  190  205  265  305  370  400  460  580  750  —  860  1060  —  —
 AC-1 Rated operational current  θ ≤ 40 °C, 690 V   A  25  28  30  45  50  50  70  100  105  125  130  160  200  225  275  350  400  500  600  600  700  800  1050  1260  1350  1650  2050  2650


 UL / CSA 1-phase motor rating  120 V  hp  0.75  1  1.5  2  2  2  3  3  5  7.5  7.5  —  —  —  —  —  —  —  —  —  —  —  —  —  —  —  —  —
 240 V  hp  1.5  2  3  3  5  5  7.5  10  15  15  20  —  —  —  —  —  —  —  —  —  —  —  —  —  —   —      —     —
 3-phase motor rating  200 - 208 V  hp  2  3  5  7.5  10  10  10  15  20  25  30  30  40  40  50  60  75  100  125  125  150  200  250  —  —  —  —  —
 220 - 240 V  hp  2  3  5  7.5  10  10  15  20  25  30  30  40  50  50  60  75  100  125  150  150  200  250  300  —  400  450  —  —
 440 - 480 V  hp  5  7.5  10  15  20  25  30  40  50  60  60  75  100  100  125  150  200  250  300  350  400  500  600  —  800  900  —  —
 550 - 600 V  hp  7.5  10  15  20  25  30  40  50  60  75  75  100  125  125  150  200  250  300  350  400  500  600  700  —  1000  1150  —  —
 General use rating  600 V    A  25  28  30  45  50  50  60  80  90  105  115  160  200  200  250  300  350  400  520  550  650  750  900  1210  1350  1650  2100  2700
 NEMA  NEMA Size  00  0  —  1  —  —  2  —  —  3  —  —  4  —  —  —  5  —  —  —  6  —  7  —  —    8      —     —


 Main accessories
 Auxiliary contact blocks  Front mounting  CA4-10 (1 x N.O.)
 CA4-01 (1 x N.C.)
 Side mounting  CAL4-11 (1 x N.O. + 1 x N.C.)  CAL19-11 (1 x N.O. + 1 x N.C.)  CAL18-11 (1 x N.O. + 1 x N.C.)
 Timers  Electronic  TEF4-ON
 TEF4-OFF
 Interlocking units  Mechanical  VM4  VM96-4  VM19 (for same size contactors)  VM750H    VM1650H
                                                         VM750V
 Mechanical / Electrical  VEM4
 Connection sets  For reversing contactors  BER16-4  BER38-4  BER65-4  BER96-4  BER140-4  BER205-4  BER370-4  BEM460-30  BEM750-30
 Surge suppressors  Built-in surge protection


 Overload relays
 Thermal relays  Class 10  TF42 (0.10…38 A)  TF65 (22...67 A)  TF96 (40...96 A)  TF140DU (66...142 A)  TA200DU (66...200 A)
 (Class 10A for TF140, TA200DU)  θ ≤ 55 °C  θ ≤ 55 °C
 Electronic relays  Class 10E, 20E, 30E  EF19 (0.10…18.9 A)  EF19 (0.10…18.9 A)  EF65 (20...70 A)  EF96 (36...100 A)  EF146 (54...150 A)  EF205 (63...210 A)  EF370 (115...380 A)  EF460 (150…500 A)  EF750 (250…800 A)  E1250DU (375…1250 A)
 EF45 (9…45 A)


 Manual motor starters  Short-circuit protection devices
 Thermal / magnetic protection  MS116 (0.10...32 A)  MS165 (10...65 A)  MS5100 (40…100 A)  MCCB and switch-fuses
 Class 10  lcs up to 50 kA for class 10 A  lcs up to 100 kA (1)  Ics up to 50 kA
 MS132 (0.10...32 A)  MS495 (45…100 A)
 lcs up to 100 kA  Ics up to 50 kA
 MS497 (22…100 A)
 Ics up to 100 kA
 Magnetic only types  MO132 (0.16...32 A)  MO165 (16...65 A)  MO5100 (70…100 A)
 Ics up to 100 kA  lcs up to 100 kA (1)  Ics up to 36 kA
 MO496 (32…100 A)
 Ics up to 100 kA
 MO495 (63…100 A)
 Ics up to 50 kA                                                                                                    1SBC101908S0201 - Rev. C
 Accessories  For contactor mounting  BEA16-4  BEA38-4  BEA65-4 (2)
 (1) MS165/MO165 are suitable for use with AF09 ... AF30 for North american applications.
 (2) BEA65-4 suitable for MS165 and MO165 only.

                                                                         ABB  Motor protection and control - short form catalog  |  5/33