Page 108 - 1SBC100195C0203_Short_form_motor_protection_ control
P. 108

Time)
                                                                                                                               Time)
                                                                                                                               Time)

       3-pole contactors, for motor control and power switching



















       AC / DC Control supply                   Type  AF09  AF12  AF16  AF26  AF30  AF38  AF40  AF52  AF65  AF80  AF96           AF116  AF140  AF146 AF190  AF205  AF265 AF305 AF370 AF400  AF460  AF580  AF750  AF1250 AF1350  AF1650  AF2050 AF2650
       IEC     AC-3 Rated operational power  220 - 230 - 240 V  kW  2.2  3  4  6.5  9  11  11  15  18.5   22  25                 30    37     45   55     55     75   90   110  110   132    160   220    —     257    315    —     —
                   θ ≤ 60 °C for AF09 ... AF370  380 - 400 V   kW  4  5.5  7.5  11  15  18.5  18.5   22  30  37  45              55    75     75   90     110    132  160  200  200   250    315   400    —     475    560    —     —
                   θ ≤ 55 °C for AF400 ... AF2650  415 V  kW  4  5.5  9  11  15  18.5  22  30    37   45   55                    55    75     75   90     110    132  160  200  220   250    355   425    —     500    630    —     —
                                    440 V       kW   4     5.5  9     15   18.5  22   22   30    37   45   55                    75    90     90   110    132    160  160  200  220   250    355   450    —     560    710    —     —
                                    500 V       kW   5.5   7.5  9     15   18.5  22   22   30    37   45   55                    75    90     90   110    132    160  200  250  250   315    400   520    —     560    710    —     —
    5                               690 V       kW   5.5   7.5  9     15   18.5  22   22   30    37   45   55                    55    75     90   132    160    200  250  315  315   355    500   600    —     800    1000   —     —
                                    1000 V      kW   —     —    —     —    —    —     —    —     —    35   40                    —     —      75   110    132    132  132  132  220   280    355   400    —     —      —      —     —
                   Rated operational current  380 - 400 V   A  9  12  18  26  32  38  40   53    65   80   96                    116   140    146  190    205    265  305  370  400   460    580   750    —     860    1060   —     —
               AC-1 Rated operational current  θ ≤ 40 °C, 690 V   A  25  28  30  45  50  50  70  100  105  125  130              160   200    225  275    350    400  500  600  600   700    800   1050   1260  1350   1650   2050  2650


       UL / CSA 1-phase motor rating  120 V     hp   0.75  1    1.5   2    2    2     3    3     5    7.5  7.5                   —     —      —    —      —      —    —    —    —     —      —     —      —     —      —      —     —
                                    240 V       hp   1.5   2    3     3    5    5     7.5  10    15   15   20                    —     —      —    —      —      —    —    —    —     —      —     —      —     —      —      —     —
               3-phase motor rating  200 - 208 V  hp  2    3    5     7.5    10  10   10   15    20   25   30                    30    40     40   50     60     75   100  125  125   150    200   250    —     —      —      —     —
                                    220 - 240 V  hp  2     3    5     7.5    10  10   15   20    25   30   30                    40    50     50   60     75     100  125  150  150   200    250   300    —     400    450    —     —
                                    440 - 480 V  hp  5     7.5  10    15   20   25    30   40    50   60   60                    75    100    100  125    150    200  250  300  350   400    500   600    —     800    900    —     —
                                    550 - 600 V   hp  7.5    10  15   20   25   30    40   50    60   75   75                    100   125    125  150    200    250  300  350  400   500    600   700    —     1000   1150   —     —
               General use rating   600 V        A   25    28   30    45   50   50    60   80    90   105  115                   160   200    200  250    300    350  400  520  550   650    750   900    1210  1350   1650   2100  2700
       NEMA    NEMA Size                             00    0    —     1    —    —     2    —     —    3    —                     —     4      —    —      —      5    —    —    —     6      —     7      —     —      8      —     —


       Main accessories
       Auxiliary contact blocks  Front mounting      CA4-10 (1 x N.O.)
                                                     CA4-01 (1 x N.C.)
                                 Side mounting       CAL4-11 (1 x N.O. + 1 x N.C.)                                               CAL19-11 (1 x N.O. + 1 x N.C.)                 CAL18-11 (1 x N.O. + 1 x N.C.)
       Timers                    Electronic          TEF4-ON
                                                     TEF4-OFF
       Interlocking units        Mechanical          VM4                              VM96-4                                     VM19 (for same size contactors)                VM750H                          VM1650H
                                                                                                                                                                                VM750V
                                 Mechanical / Electrical  VEM4
       Connection sets           For reversing contactors  BER16-4    BER38-4         BER65-4         BER96-4                    BER140-4          BER205-4      BER370-4       BEM460-30    BEM750-30
       Surge suppressors                             Built-in surge protection


       Overload relays
       Thermal relays            Class 10            TF42 (0.10…38 A)                 TF65 (22...67 A)  TF96 (40...96 A)         TF140DU (66...142 A)  TA200DU (66...200 A)
                                 (Class 10A for TF140, TA200DU)                                                                  θ ≤ 55 °C         θ ≤ 55 °C
       Electronic relays         Class 10E, 20E, 30E  EF19 (0.10…18.9 A)  EF19 (0.10…18.9 A)  EF65 (20...70 A)  EF96 (36...100 A)  EF146 (54...150 A)  EF205 (63...210 A)  EF370 (115...380 A)  EF460 (150…500 A)  EF750 (250…800 A)  E1250DU (375…1250 A)
                                                                      EF45 (9…45 A)


       Manual motor starters                                                                                                     Short-circuit protection devices
                                 Thermal / magnetic protection  MS116 (0.10...32 A)  MS165 (10...65 A)  MS5100 (40…100 A)        MCCB and switch-fuses
                                 Class 10            lcs up to 50 kA for class 10 A  lcs up to 100 kA (1)  Ics up to 50 kA
                                                     MS132 (0.10...32 A)                   MS495 (45…100 A)
                                                     lcs up to 100 kA                      Ics up to 50 kA
                                                                                MS497 (22…100 A)
                                                                                Ics up to 100 kA
                                 Magnetic only types  MO132 (0.16...32 A)       MO165 (16...65 A)     MO5100 (70…100 A)
                                                     Ics up to 100 kA           lcs up to 100 kA (1)  Ics up to 36 kA
                                                                                      MO496 (32…100 A)
                                                                                      Ics up to 100 kA
                                                                                                      MO495 (63…100 A)
                                                                                                      Ics up to 50 kA
       Accessories               For contactor mounting  BEA16-4      BEA38-4         BEA65-4 (2)
       (1) MS165/MO165 are suitable for use with AF09 ... AF30 for North american applications.
       (2) BEA65-4 suitable for MS165 and MO165 only.

       5/32  |  ABB  Motor protection and control - short form catalog
   103   104   105   106   107   108   109   110   111   112   113