Page 514 - Motor protection and control Manual motor starters, contactors and overload relays
P. 514

3/440            ABB  MOTOR PROTECTION AND CONTROL

          —
          Questionnaire for product specifications:

          Block contactors




          Tel.:      e-mail:                                    Tel.:      e-mail:
          Segments:                                             Date:
   03




            Application
                                                                 Control circuit
            Type:     No of phases:
            Utilisation category (AC/DC):    %  AC4 if any:      Rated control Uc voltage:  V    DC    AC  f:   Hz
            Rated operational voltage Ue:       V     Cos j:     Minimum / maximum:    V    to    V
                                                                 Surge suppressor:     type:
                          Frequency:     Hz   L/R:    ms         Interface with PLC:    mA        V DC
            Nominal current In:    A                             Accessories:
            Making current:  A    Breaking current:    A         Number of auxiliary contacts:  N.O.:     N.C.:
            Duty:    continuous     temporary     intermittent   Low level contacts:    mA      V   DC    AC
            Load factor (% of ON time):     %
            Number of cycles per hour:     or per year:
            Expected durability:     operating cycles
            Number of main poles N.O.:     N.C.:                Protection
            Other information:
                                                                Short circuit protection:
                                                                Type:   Fuse    Circuit breaker    Manual motor starter
                                                                Max short circuit current:   A
                                                                Motor protection:   Overload relay    Manual Motor
                                                                Starter   Electronic overload relay
            Installation

            Ambient temperature:
            Ambient environment:
            Humidity:     %                                    Logistic and packaging
            Chemical pollution:                                Quantity by batch:
            Other:                                             Delivery order:
            Mounting position, see drawing below (Position 6:   Expected quantity:     per year
            please consult factory):
                                                               Expected first delivery date:    and Qty:
                                                               Quantity on first 6 month:     on first year:
                Pos. 2   +30°  -30°

            Pos. 4
                    Pos. 3
                                                                Approvals and other requirements
                  Pos. 1    Pos. 1 ± 30°  Pos. 5   Pos. 6
                                                                Reference standards:
                                                                Required approvals:
            Wiring:   Clamping screws or cage connectors        Customer specifications:
              Cable lugs (ring tongue)
            Other:   Cross section:                             Shock and vibrations:
                                                                Specific quality assurance clauses:
            Additional comments:
                                                                Other comments:









                                                                                                                 1SBC101701S0201
   509   510   511   512   513   514   515   516   517   518   519