Page 34 - 1SBC104119C0202_MainCatalog_R contactors
P. 34

IORR63..MT … IORR500..MT and
IORE63..MT … IORE500..MT contactors
Technical data

Main pole - Utilization characteristics according to IEC

Contactor types                                   AC operated IORR63..MT           IORR125..MT IORR200..MT          IORR400..MT  IORR500..MT
                                                                                                                    IORE400..MT  IORE500..MT
                                                  DC operated IORE63..MT           IORE125..MT IORE200..MT
                                                                                                                    400 A        550 A
Standards                                                       IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1  240 mm²      400 mm²

Rated operational voltage Ue max.                               1000 V                                              400 A        550 A
                                                                                                                    350 A        490 A
Rated frequency (without derating)                              25…60 Hz (for > 60...400 Hz please consult us)      300 A        400 A
                                                                                                                    240 mm²      400 mm²
Number of poles                                                 2...4

      Conventional free-air thermal current Ith                 85 A               170 A            275 A
                                                                25 mm²             70 mm²           150 mm²
3 acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C
           With conductor cross-sectional area

AC-1 Utilization category

For air temperature close to contactor

Ie / Rated operational current AC-1                  θ ≤ 40 °C  85 A               170 A            260 A
Ue max. ≤ 1000 V, 50/60 Hz                           θ ≤ 55 °C  76 A               150 A            230 A
                                                     θ ≤ 70 °C  68 A               135 A            205 A
With conductor cross-sectional area                             25 mm²             70 mm²           150 mm²

AC-3 Utilization category

For air temperature close to contactor θ ≤ 55 °C
    Ie / Max. rated operational current AC-3

   M                                                  690 V 85 A                   160 A            260 A           400 A        550 A
  3                                                  1000 V 56 A                   105 A            180 A           280 A        380 A

Rated operational power AC-3

M                                                     690 V     80 kW              150 kW           240 kW          400 kW       540 kW
                                                     1000 V                                         250 kW          400 kW       550 kW
3                                                               80 kW              150 kW
                                                                                                    315 A           500 A        630 A
Rated making capacity AC-3                                      10 x Ie AC-3 acc. to IEC 60947-4-1  -               -            -
                                                                                                    3800 A          6000 A       8400 A
Rated breaking capacity AC-3                                    8 x Ie AC-3 acc. to IEC 60947-4-1   2080 A          3200 A       4400 A
                                                                                                    1040 A          1600 A       2200 A
Short-circuit protection device for contactors                                                      730 A           1200 A       1680 A
                                                                                                    390 A           600 A        840 A
without thermal overload relay - Motor protection excluded
                                                                                                    2100 A          4480 A       4480 A
Ue ≤ 1000 V AC - gG type fuse                                   100 A              200 A            1450 A          3050 A       3050 A
                                                                -                  -                4000 A          7000 A       9000 A
Ue ≤ 1000 V AC - L type fuse                                    1150 A             2250 A           4500 A          8000 A       10000 A
                                                                680 A              1280 A           0.60 mΩ         0.40 mΩ      0.35 mΩ
Rated short-time withstand current Icw                      1s  310 A              680 A
                                                                230 A              450 A
at 40 °C ambient temperature,                        10 s       120 A              250 A

in free air from a cold state                        30 s       680 A              1280 A
                                                                450 A              850 A
                                                     1 min      1300 A             2400 A
                                                                1400 A             2500 A
                                                     15 min     1.8 mΩ             1.20 mΩ
                                                                300 cycles/h
Maximum breaking capacity                                       300 cycles/h
                                                                150 cycles/h
cos φ = 0.45                                         at 690 V
                                                                5 millions cycles
(cos φ = 0.35 for Ie > 100 A)                        at 1000 V  1200 cycles/h
Maximum making capacity

Dynamical withstand of pole

Impedance per pole

Maximum electrical switching frequency               AC-1

                                                     AC-3

                                                     AC-4

Mechanical durability

Number of operating cycles

Max. switching frequency

Note: These characteristics are suitable for IOR..MT-AMA and IOR..MT-AME contactors with latching versions (except for mechanical durability = 0.2 millions of operating cycles).

                                                                                                                                                                                   1SBC104027S0201