Page 62 - Current & voltage sensors catalog
P. 62
CS300 ... CS1000 railway current sensors
For rolling stock and infrastructure
Dimensions (mm)
Horizontal mounting Vertical mounting
15.2 15.2 12.7
15.2 15.2
3 x M5 3 x M5
ø 27.5 13
13
4 x ø 5.5
ø 26
3 101 101
60 84 84
10
20
31 31
26 52
70
33
86 58
64
70
6
86
28.2
ø 13 M6 55
46
+ M – E + M – E 25
G0174D
3 Faston 6.35 x 0.8
ø 5.5 125
ø 6.3
Size 0 - CS300BR 5.5 6.3 3 Faston 155 G0175D
6.35 x 0.8
and CS503BR
Size 0 - CS300BRV Bar CST0
Horizontal mounting Vertical mounting
15.2 15.2 19 15.2 15.2 65
3 x M5 ø 40.8 3 x M5 ø 40
4 x ø 5.5 12 12
126
113 126
78 12 113
55 55
40
44
78 100 81
70
6
100
37.5 ø 13 M6 67
66
+ M – E + M – E 40
General tolerance: ±1 mm
G0176D
3 Faston 6.35 x 0.8 145
185
Size 1 - CS500BR ø 6.5 ø 6.3
and CS1000BR 6.5 6.3 3 Faston Bar CST1-6
6.35 x 0.8
10
Size 1 - CS500BRV
and CS1000BRV
ø 13 M6 67
40
General tolerance: ±1 mm
145
185 G0177D
Bar CST1-10 1SBC140040S0201
The primary bar kit is only available with the vertical mounting versions.
Tightening torque for M5 terminal studs (N.m) : 2