Page 269 - EPR Catalog 2015
P. 269

CP-B range
Technical data, Technical diagrams

Type                                                                                      CP-B 24/3.0                 CP-B 24/10.0                                                          CP-B 24/20.0

Input circuit - Supply circuit                                                                                        L+IN L-IN
Signalling circuit
Wire size                           fine-strand with(out) wire end ferrule 0.08-1.0 mm² (28-18 AWG)                                                                                         0.14-1.0 mm² (26-16 AWG)
                                                                                 rigid 0.08-1.5 mm² (28-16 AWG)                                                                             0.14-1.5 mm² (28-16 AWG)
Stripping length
                                                                                         6.0 mm (0.24 in)                                                                                   7.0 mm (0.28 in)

Environmental data

Ambient temperature                                   operation -40...+60 °C                                                                                                                -20...+60 °C

                                                                      storage -40...+60 °C                                                                                                  -20...+60 °C                                  3

Standards

Product standard                                                                          EN 50178

Low Voltage Directive                                                                     2006/95/EC

EMC Directive                                                                             2004/108/EC

RoHS Directive                                                                            2011/65/EC

Electrical safety                                                                         EN 50178, EN 60950, UL 508

Electromagnetic compatibility

Interference immunity to                                                                  IEC/EN 61000-6-1, IEC/EN 61000-6-2

electrostatic discharge                               IEC/EN 61000-4-2 Level 3, 6 kV / 8 kV

radiated, radio-frequency, electromagnetic field      IEC/EN 61000-4-3 Level 3, 10 V/m (27-1000 MHz) / Level 2, 3 V/m (1400-2700 MHz)

electrical fast transient/burst                       IEC/EN 61000-4-4 Level 3, 2(1) kV / 5 kHz

surge                                                 IEC/EN 61000-4-5 Level 1, 0.5 kV

conducted disturbances, induced by radio-             IEC/EN 61000-4-6 Level 3, 10 V (150 kHz-80 MHz)
frequency fields

voltage dips, short interruptions and voltage         IEC/EN 61000-4-11 buffered by ultra-capacitors
variations

Interference emission                                                                     EN 61000-6-3, EN 61000-6-4

high-frequency radiated                               DIN EN 55011 B/C1

high-frequency conducted                              DIN EN 55011 B/C1

„Approvals and marks“ on page 3/4.

1) buffering time ≈  energy storage x 0.9
                     load current x output voltage

Technical diagrams
Output curve at Ta = 25 °C

  Iout [A]                          Normal application (up to                              Iout [A]                                                                     Normal application (up to
3.0                                 50 % buffer mode, 5 charging                                                                                                        50 % buffer mode, 5 charging
                                    and discharging cycles in                             20                                                                            and discharging cycles in
1.5                                 direct series)                                        15                                                                            direct series)
                                                                                          10
                                    Continuous charging and                                                                                                             Continuous charging and
                                    discharging in direct series.     2CDC 272 028 F0210                                                                                discharging in direct series.                 2CDC 272 030 F0210
                                    As this is not typical of a real                                                                                                    As this is not typical of a real
                                    application, this should                                      Years                                                                 application, this should
                                    be considered as theoretical                                                                                                        be considered as theoretical
                                    indication                                                                                                                          indication

                                    Ta [°C]                                                                                                                             Ta [°C]

-40 0              20 40 60                                                                              -20 0  20 40 60

CP-B 24/3.0                                                                               CP-B 24/20.0

   Iout [A]                         Normal application (up to                                            60
                                    50 % buffer mode, 5 charging
10.0                                and discharging cycles in                                            50
 7.5                                direct series)
 5.0                                                                                                     40
                                    Continuous charging and
                                    discharging in direct series.     2CDC 272 029 F0210                 30                                                             2CDC 272 031 F0210
                                    As this is not typical of a real
                                    application, this should                                             20
                                    be considered as theoretical
                                    indication                                                           10

                                    Ta [°C]                                                                0
                                                                                                             10 20 30 40 50 60 70
-40 0                20 40 60                                                                                                                           Temperature [°C]

CP-B 24/10.0                                                                                             Capacitor's life span over temperature

Caracteristic curve of the temperature at rated load

                                                                                          2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 3/70
   264   265   266   267   268   269   270   271   272   273   274