Page 143 - index
P. 143
Contacteur Circuit de commande AC IORR63..-MT IORR125..-MT IORR200..-MT IORR400..-MT IORR500..-MT IORR800..-MT IORR1400..-MT IORR1700..-MT IORR2100..-MT IORR2500..-MT IORR3200..-MT IORR3800..-MT IORR4500..-MT IORR5100..-MT
type
Circuit de commande DC IORE63..-MT IORE125..-MT IORE200..-MT IORE400..-MT IORE500..-MT IORE800..-MT IORE1400..-MT IORE1700..-MT IORE2100..-MT IORE2500..-MT IORE3200..-MT IORE3800..-MT IORE4500..-MT IORE5100..-MT
Catégories d'emploi Ue
AC-1 à 40 °C Ie 85 A 170 A 260 A 400 A 550 A 800 A 1250 A 1650 A 1850 A 2200 A 3000 A 3500 A 4000 A 4500 A
AC-3 690 V AC Ie 85 A 160 A 260 A 400 A 550 A 800 A 970 A 1170 A 1270 A – – – – –
1000 V AC max. Ie 56 A 105 A 180 A 280 A 380 A 580 A 610 A 680 A 810 A – – – – –
AC-3 690 V AC kW 80 kW 150 kW 240 kW 400 kW 540 kW 780 kW 1000 kW 1200 kW 1300 kW – – – – –
8
Contacteur Circuit de commande AC – IORR800 IORR1000 IORR1400 IORR1700 IORR2100 IORR2500 IORR3200 IORR3800 IORR4500 IORR5100
type
Circuit de commande DC – IORE800 IORE1000 IORE1400 IORE1700 IORE2100 IORE2500 IORE3200 IORE3800 IORE4500 IORE5100
Catégories d'emploi Ue
85 A 550 A,
AC-1 à 40 °C Ie De à utiliser le tableau ci-dessus IOR..-MT 900 A 1000 A 1350 A 1650 A 2000 A 2400 A 3200 A 3800 A 4500 A 5000 A
AC-3 380-415-440 V AC Ie – – 800 A 800 A 1060 A 1260 A 1520 A – – – – –
500 V AC max. Ie – – 800 A 800 A 1080 A 1220 A 1340 A – – – – –
AC-3 400 V AC kW – – 450 kW 450 kW 630 kW 750 kW 900 kW – – – – –
ABB Protection et commande de moteur | 8/5