Page 219 - Motor_protection_and_control_Manual_motor_starters_ contactors
P. 219

DOL starters protected by MS165 manual motor starters

         With AF contactors - open type version in kit form





         Main dimensions mm, inches
                 * For Ue>400V          127.6  5.02"   10  0.39"                 6  0.24"  10  35  1.38"  10
                         75  2.95"
               *1.5  0.06" *1.5  0.06"  95.5  3.76"                               0.39"       0.39"
                                                                                               ø 4.6  0.18
                                                                                               M4  8-32 UNC
                                    5.3
                                    0.21"
                              68.8  2.71”                                                      ø 8.6  0.34
                                    5.5
                                    0.22"




          290  11.42”  287.3  11.31”  151.9  5.98”  35 mm EN/IEC 60715           273.4  10.76"  268.4  10.57"  40  1.57"  5



                                2X
                                    5.5
                                    0.22"
                                                                                               ø 4.2  0.17
                                                                                               M4  8-32 UNC
                                                                                               ø 6.4  0.25
                                                                                               M6  1/4-20 UNC
                               7  0.28"  111  4.37"  10  0.39"                     5    45  1.77"  5
                 55  2.17"
            6  0.24"                                                             4.6  0.18"  0.2"  0.2"
         MS165
         + BEA65-4
         + AF40, AF52, AF65



                 * For Ue>400V          127.6  5.02"   10  0.39"
                         75  2.95"
               *1.5  0.06" *1.5  0.06"  95.5  3.76"
             * For Ue>400V  75  2.95"  5.5  0.22"  122.1  4.81"  10  0.39"
                                    5.3
           *1.5  0.06"  *1.5  0.06"  0.21"      95.5  3.76"
                              68.8  2.71”
                                    0.22"45.7  1.80" 5.5






          290  11.42”  288  11.34"  287.3  11.31”  287.3  11.31"  151.9  5.98”  35 mm EN/IEC 60715  195  7.68"  2x35mm EN/IEC60715



                                2X                          10  0.39"

                                    5.5
                                   0.22"

                                    (1)
                                        BPR65-4
                               7  0.28"  111  4.37"  10  0.39"
                 55  2.17"
            6  0.24"  6.5  0.26"  55  2.17"  6  0.24"  5.5  0.22"  105.5  4.15"
         MS165
         + BEA65-4                                                                                                  1SBC100088S0201 - Rev. B
         + AF40, AF52, AF65 + BPR65-4
         Note: for Ue > 400 V, contactor lateral distance to grounded component 1.5 mm 0.06" min.
         (1) Assembly on fixed DIN Rails for DOL starter with BPR65-4 rail hook

                                                                                                          ABB  |  5/19
   214   215   216   217   218   219   220   221   222   223   224