Page 51 - contactors_motor_protection_for_rolling_stock_application
P. 51
Technical data
MS132-B, MS165-B, MO132-B, MO165-B
General technical data
Type MS132-B MS165-B MO132-B MO165-B
Pollution degree 3 3 3 3
Phase loss sensitivity Yes Yes No No
Disconnect function acc. to IEC/EN 60947-2 Yes Yes Yes Yes 2
Ambient air temperature
Operation Open - compensated -25 ... +60 °C -25 ... +60 °C - -
Open -25 ... +70 °C -25 ... +60 °C -25 ... +60 °C -25 ... +60 °C
Enclosed (IB132 ) 0 ... +40 °C - - -
1)
Storage -50 ... +80 °C -50 ... +80 °C -50 ... +80 °C -50 ... +80 °C
Ambient air temperature compensation Acc. to IEC/EN60947-4-1 Acc. to IEC/EN60947-4-1 - -
Maximum operating altitude permissible 2000 m 2000 m 2000 m 2000 m
Shock and vibration withstand acc. to IEC 61373 Category 1, Class B Category 1, Class B Category 1, Class B Category 1, Class B
Mounting position Position 1-6 (optional for Position 1-6 (optional for Position 1-6 (optional for Position 1-6 (optional for
single mounting) single mounting) single mounting) single mounting)
Mounting DIN-rail (EN 60715) DIN-rail (EN 60715) DIN-rail (EN 60715) DIN-rail (EN 60715)
Group mounting On request On request On request On request
Recommended screw for mounting plate - M4 - M4
Screw torque for mounting plate - 2 Nm - 2 Nm
Minimum distance to other Horizontal 0 mm 0 mm 0 mm 0 mm
units same type Vertical 150 mm 150 mm 150 mm 150 mm
Minimum distance to Horizontal, up to 400 V 0 mm 0 mm 0 mm 0 mm
electrical conductive board Horizontal, up to 690 V > 1.5 mm > 1.5 mm > 1.5 mm > 1.5 mm
Vertical 75 mm 75 mm 75 mm 75 mm
Degree of protection Housing IP20 IP20 IP20 IP20
Main circuit terminals IP10 IP10 IP10 IP10
1) not suitable for MS165-B and MO165-B
2CDC131100C0201
ABB | 2/39