Page 68 - Current & voltage sensors catalog
P. 68

NCS165T railway current sensors
       For infrastructure only

       Technical data


       Utilisation
       Sensors to measure DC, AC or pulsating currents with
       a galvanic insulation between primary and secondary
       circuits.



    3


                                        Output current shielded cable NCS165T-4AF  –  NCS165T-6AF  –
                                        Output voltage shielded cable –  NCS165T-4VF  –            NCS165T-6VF
       Nominal primary current                           A 4000         4000          6000         6000
       Measuring range                                   A 20000        20000         30000        30000
       Not measured overload          1 s/h          A peak 80000       80000         120000       120000
       Secondary current I S1 at I PN                  mA ±20           –             ±20          –
                                                       mA ±20           –             ±20          –
       Secondary current I S2 at I PMAX
       Residual current I S10         @ +25 °C          μA ≤±250        –             ≤±250        –
       Residual current I S20         @ +25 °C          μA ≤±180        –             ≤±180        –
       Thermal drift coefficient (outputs I S1, I S2)  μA/°C ≤±4        –             ≤±4          –
       Measuring resistance (outputs I S1, I S2)         Ω 0 ... 350    –             0 ... 350    –
       Secondary voltage V S1 at I PN                    V –            ±10           –            ±10
                                                         V –            ±10           –            ±10
       Secondary voltage V S2 at I PMAX
       Residual voltage V S10         @ +25 °C          mV –            ≤±100         –            ≤±100
       Residual voltage V S20         @ +25 °C          mV –            ≤±50          –            ≤±50
       Thermal drift coefficient (outputs V S1, V S2)  mV/°C –          ≤±2           –            ≤±2
       Measuring resistance (outputs V S1, V S2)         Ω –            10000 ... ∞   –            10000 ... ∞
       Rms accuracy 50 Hz (without offset) (1) at I PN  @ +25 °C  % ≤±1  ≤±1          ≤±1          ≤±1
                                      @ +25 °C          % ≤±3           ≤±3           ≤±3          ≤±3
       Rms accuracy 50 Hz (without offset) (1) at I PMAX
       Gain thermal drift             -25 ... +85 °C  %/°C ≤0.03        ≤0.03         ≤0.03        ≤0.03
       Gain thermal drift             -40 ... -25 °C  %/°C ≤0.1         ≤0.1          ≤0.1         ≤0.1
       Linearity (typical)                              % ±0.5          ±0.5          ±0.5         ±0.5
       Delay time (typical)                             μs ≤3           ≤3            ≤3           ≤3
       di/dt correctly followed                       A / μs ≤100       ≤100          ≤100         ≤100
       Bandwidth                      @ -1 dB          kHz 0 … 10       0 … 10        0 … 10       0 … 10
       No load consumption current (I A0+)  @ -40 °C   mA ≤210          ≤210          ≤210         ≤210
       No load consumption current (I A0-)             mA ≤35           ≤35           ≤35          ≤35
       Dielectric strength Primary/Secondary  50 Hz, 1 min  kV r.m.s. 20  20          20           20
       Supply voltage                 ± 25%           V DC ±24          ±24           ±24          ±24
       Mass                                             kg 1.7          1.7           1.7          1.7
       Operating temperature                            °C -40 … +85    -40 … +85     -40 … +85    -40 … +85
       Storage/startup temperature                      °C -50 … +90    -50 … +90     -50 … +90    -50 … +90
       (1) Maximum current I PN generated: 5000 A r.m.s.







        General data                                         Primary connection
           – Plastic case and insulating resin are self-extinguishing.  Hole for primary conductor.
           – Two fixing modes:                                The temperature of the primary conductor in contact with the case
            - Horizontal or vertical with fixing holes in the case moulding.  must not exceed 100 °C.
            - By bar using the intermediate side plate kit (Refer to accessories
           and options on the following page)
           – Max tightening torque for M6 screws (side plate mounting): 2 N.m  Secondary connection
           – Direction of the current:                       Shielded cable 6 x 2000 mm (cross section 0.5 mm²)
            - Output current (I S1 and I S2): A primary current flowing in the
           direction of the arrow results in a positive secondary output cur-
           rent on terminals I S1 and I S2.
            - Output voltage (V S1 and V S2): A primary current flowing in the
           direction of the arrow results in a positive secondary output volt-
           age on terminals V S1 and V S2.
           – Burn-in test in accordance with FPTC 404304 cycle



       66  |  ABB