Type CP-ASI/2.8 CP-ASI/4.0 CP-ASI/8.0 CP-ASI/4.0 DC/DC
General data
typ. < 12.7 W
MTBF on request (24 V DC, 4.0 A)
typ. 90.5 %
Power dissipation typ. < 9.1 W typ. < 13.5 W typ. < 21.2 W 40 x 131 x 107 mm
(1.58 x 5.16 x 4.21 in)
Efficiency (230 V AC, 2.8 A) (230 V AC, 4.0 A) (230 V AC, 8.0 A) 151 x 65 x 140 mm
Duty time (5.94 x 2.56 x 5.51 in)
Dimensions (W x H x D) typ. 90.5 % typ. 90 % typ. 92.0 % 0.488 kg (1.076 lb)
0.750 kg (1.287 lb)
Weight 100 %
-25...+70 °C
Material of housing product dimensions 49 x 131 x 107 mm 73 x 131 x 107 mm 91 x 131 x 107 mm -25...+60 °C
Mounting -40...+85 °C
Mounting position (1.93 x 5.16 x 4.21 in) (2.87 x 5.16 x 4.21 in) (3.58 x 5.16 x 4.21 in)
Minimum distance to other units 50 V
Degree of protection packaging dimensions 151 x 65 x 140 mm 151 x 98 x 140 mm 151 x 120 x 140 mm 50 V 3
Protection class
Electrical connection (5.94 x 2.56 x 5.51 in) (5.94 x 3.86 x 5.51 in) (5.94 x 4.72 x 5.51 in) 1.5 kV 1.2/50 μs
0.8 kV 1.2/50 μs
net weight 0.495 kg (1.019 lb) 0.653 kg (1.440 lb) 0.897 kg (1.997 lb) 500 V 1.2/50 μs
1.5 kV AC /
gross weight 0.568 kg (1.252 lb) 0.750 kg (1.653 lb) 1.015 kg (2.238 lb) 1.5 kV AC
1.5 kV AC /
metal 1.5 kV AC
DIN rail (IEC/EN 60715), snap-on mounting without any tool input circuit:
Level 3 (2 kV)
horizontal output circuit:
Level 2 (1 kV)
horizontal / vertical 15 mm / 25 mm (0.59 / 0.99 in) input circuit: L-L Level 2
(1 kV) / L-PE Level 3 (2 kV)
housing / terminals IP20 / IP20 output circuit:
Level 1 (0.5 kV)
I Level 3 (10 V, 150
kHz - 80 MHz)
Wire size fine-strand with wire end ferrule 0.5-4 mm² (20-12 AWG)
fine-strand without wire end ferrule 0.5-4 mm² (20-12 AWG) IEC/EN 61000-6-3
Stripping length
Tightening torque rigid 0.5-6 mm² (20-10 AWG) -
7 mm (0.28 in)
0.8 Nm (7.08 lb.in)
Environmental data
Ambient temperature range operation -10...+70 °C
rated load -10...+60 °C
Vibration (sinusoidal)
(IEC/EN 60068-2-6) storage -25...+85 °C
2-17.8 Hz, amplitude ± 1.6 mm
sinusoidal (IEC/EN 60068-2-6) 17.8 Hz - 500 Hz, 2 g
random (IEC 60068-2-64) 2-800 Hz 0.5 s² (s³)
Shock (half-sine) (IEC/EN 60068-2-27) 15 g (6 ms), 10 g (11 ms)
Isolation data
Rated insulation voltage Ui input circuit / output circuit 300 V
(IEC/EN 60950-1, EN 50178) input / PE 300 V
Rated impulse withstand voltage Uimp output / PE 50 V
(EN 50178) shield / output 50 V
Power-frequency withstand voltage
test (test voltage) (routine test / shield / PE 50 V
type test) input / output 6 kV 1.2/50 μs
input / PE 4 kV 1.2/50 μs
output / PE 500 V 1.2/50 μs
input / output 2.5 kV AC / 3.0 kV AC
input / PE 2.5 kV AC / 2.5 kV AC
Pollution degree (IEC/EN 60950-1) output / PE 500 V AC / 500 V AC
Overvoltage category (UL/IEC/EN 60950-1) 2
input II (IEC/EN 60950-1), III (EN 50178)
output II (IEC/EN 60950-1), II (EN 50178)
Standards 2006/95/EC
2004/108/EC
Low Voltage Directive 2011/65/EC
EMC directive IEC/EN 60950-1
RoHS directive SELV (IEC/EN 60950-1), PELV
Electrical safety
Protective low voltage IEC/EN 61000-6-2
IEC/EN 61000-4-2 Level 4 (8 kV / 15 kV)
Electromagnetic compatibility
Interference immunity to
electrostatic discharge
radiated, radio-frequency, IEC/EN 61000-4-3 Level 3 (10 V/m)
electromagnetic field IEC/EN 61000-4-4 input circuit: Level 4 (4 kV)
electrical fast transient/burst
output circuit: Level 3 (2 kV)
surge IEC/EN 61000-4-5 input circuit: L-L Level 3 (2 kV) / L-PE Level 4 (4 kV)
output circuit: Level 1 (0.5 kV)
conducted disturbances, induced by IEC/EN 61000-4-6 Level 3 (10 V, 150 kHz - 80 MHz) IEC/EN 61000-6-4
radio-frequency fields -
voltage dips, short interruptions and IEC/EN 61000-4-11 Class 3
voltag variations
Interference emission IEC/EN 61000-6-3
high-frequency radiated IEC/CISPR 22, EN 55022 Class B
high-frequency conducted IEC/CISPR 22, EN 55022 Class B
limits for harmonic current emissions
IEC/EN 61000-3-2 Class A