Page 685 - Motor_protection_and_control_Manual_motor_starters_ contactors
P. 685
AF09..S ... AF26..S 3-pole contactors - with spring terminals
Terminal marking and positioning
AF09..S ... AF26..S contactors - AC / DC operated
Standard devices without addition of auxiliary contacts
A1 A2 A1 A2 A1 A2
1L1 3L2 5L3 13 1L1 3L2 5L3 21 1L1 3L2 5L3
NO NC
A1 1L1 3L2 5L3 13 A1 1L1 3L2 5L3 21 A1 1L1 3L2 5L3
NO NC
NO NC
2T1 4T2 6T3 14 2T1 4T2 6T3 22 2T1 4T2 6T3
A1 A2 A1 A2 A1 A2 A2 2T1 4T2 6T3 NO A2 2T1 4T2 6T3 NC A2 2T1 4T2 6T3
14
22
AF09 ... AF16..-30-10S AF09 ... AF16..-30-01S AF26..-30-00S AF09 ... AF16..-30-10S AF09 ... AF16..-30-01S AF26..-30-00S
A1 A2 A1 A2 A1 A2
1L1 3L2 5L3 1L1 3L2 5L3 1L1 3L2 5L3
13 21 31 43 13 21 13 21 31 43
NO NC NC NO NO NC NO NC NC NO
A1 1L1 3L2 5L3 13 21 31 43 A1 1L1 3L2 5L3 13 21 6
14 22 32 44 14 22 14 22 32 44 NO NC NC NO NO NC
2T1 4T2 6T3 2T1 4T2 6T3 2T1 4T2 6T3
A1 A2 A1 A2 A1 A2 A2 2T1 4T2 6T3 NO NC 22 NC 32 NO 44 A2 2T1 4T2 6T3 NO NC
14
22
14
AF09 ... AF16..-30-22S AF26..-30-11S AF26..-30-22S AF09 ... AF26..-30-22S AF26..-30-11S
Other possible contact combinations with auxiliary contacts added by the user
A1 1L1 3L2 5L3 13 21
A1 A2 A1 A2 A1 A2 A1 A2 NO NC
1L1 3L2 5L3 13 1L1 3L2 5L3 13 1L1 3L2 5L3 1L1 3L2 5L3
NO NO
21 2- -1 13 21 1- 2- -3 -1 A2 2T1 4T2 6T3 NO NC 22
14
NC = + NC NO NC = + NO + NC Combination 11
22 2- -2 14 22 1- 2- -4 -2
NO NO
2T1 4T2 6T3 14 2T1 4T2 6T3 14 2T1 4T2 6T3 2T1 4T2 6T3
A1 A2 A1 A2 A1 A2 A1 A2
Combination 11 = AF09 ... AF16..-30-10S + CA4-01S Combination 11 = AF26..-30-00S + CA4-10S + CA4-01S
A1 1L1 3L2 5L3 13 21 33
A1 A2 A1 A2 NO NC NO
1L1 3L2 5L3 13 1L1 3L2 5L3 13 1L1 3L2 5L3 13 1L1 3L2 5L3 13
NO NO NO NO
A1 21 33 A1 21 33 21 31 43 53 21 31 43 53 A2 2T1 4T2 6T3 NO NC NO
22
34
14
NC NO = + NC NO NC NC NO NO = + NC NC NO NO Combination 21
22 34 A2 22 34 A2 22 32 44 54 22 32 44 54 A1 1L1 3L2 5L3 13 21 31 43 53
NO NO NO NO NO NC NC NO NO
2T1 4T2 6T3 14 2T1 4T2 6T3 14 2T1 4T2 6T3 14 2T1 4T2 6T3 14
A1 A2 A1 A2 NO NC NC NO NO
A2 2T1 4T2 6T3 14 22 32 44 54
Combination 21 = AF09 ... AF16..-30-10S + CAT4-11MS Combination 32 = AF09 ... AF16..-30-10S + CA4-22MS Combination 32
A1 A2 A1 A2
NO 1L1 3L2 5L3 13 NO 1L1 3L2 5L3 13
13X NO 13X NO
21X 21X
NC NC
= +
NC NC
A1 1L1 3L2 5L3 13 13X 21X
22X 22X NO NO NC
14X NO 14X NO
NO 2T1 4T2 6T3 14 NO 2T1 4T2 6T3 14
A1 A2 A1 A2 NO NO NC
A2 2T1 4T2 6T3 14 14X 22X
Combination 21 = CAL4-11S + AF09 ... AF16..-30-10S Combination 21
1SBC101693S0201
Note: Only AF..Z contactor with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole.
ABB | 6/61