Page 18 - Current & voltage sensors catalog
P. 18
MP25, EL25 ... EL100 industry current sensors
5 to 100 A - Closed loop technology
PCB mounting
These sensors are designed for PCB mounting.
The sensor is mechanically fixed by soldering the secondary circuit pins to the PCB.
2 The primary connection can also be integrated in the sensor (pins for MP sensors, integrated
primary bar for EL…BB sensors).
The primary conductor for EL sensors can also be a cable or a bar.
For MP sensors the primary pin combination determines the sensor's nominal rating
(see technical data).
Ordering details
1SBC146031V0014 Nominal Secondary Supply Primary Secondary Type Order code
voltage
primary current
current
connection
connection
mA
A r.m.s. at I PN V DC
5 to 25* 24 or 25* ±12 … ±15 Pins 3 pins MP25P1 1SBT312500R0001
MP25P1
Nominal Secondary Supply Primary Secondary Type Order code
1SBC146030V0014 A r.m.s. at I PN V DC
voltage
current
primary current
connection
connection
mA
25 25 ±12 … ±15 Hole 3 pins EL25P1 1SBT132500R0001
Ø 7.5 mm
25 25 ±12 … ±15 Bar 3 pins EL25P1BB 1SBT132500R0002
EL25P1 to 100P2
50 50 ±12 … ±15 Hole 3 pins EL50P1 1SBT135100R0001
Ø 10 mm
50 50 ±12 … ±15 Bar 3 pins EL50P1BB 1SBT135100R0003
50 25 ±12 … ±15 Hole 3 pins EL55P2 1SBT135100R0002
Ø 10 mm
50 25 ±12 … ±15 Bar 3 pins EL55P2BB 1SBT135100R0004
100 50 ±12 … ±15 Hole 3 pins EL100P2 1SBT130100R0001
Ø 10 mm
100 50 ±12 … ±15 Bar 3 pins EL100P2BB 1SBT130100R0002
* see technical data "MP25P1: arrangement of primary terminals and related characteristics".
1SBC140002S0201
16 | ABB