Page 25 - PLC Automation
P. 25
PLC AUTOMATION PRODUCT FAMILY 23
01
Your requirements Application specification and
performance needs
You are looking for a well established PLC solution with a large product range for extended fea- Extremely Cost-effective small Small application Small application Medium to large Extremely demanding application
tures and large communication capability. You need particularly: cost-sensitive application • large program/data • large program/data/web application • with fast response time and complex communication
• Large memory and computing performance for your application simple • with compact PLC and large memory memory • very large program/data with industrial fieldbus and Ethernet based protocols
• High Ethernet capability with secured communication and support of communication network application number of onboard I/Os • medium-complex commu- • good capability for com- and web server memory • highly-complex OPC UA communication and MQTT
with extensive Modbus TCP communication • with compact • effective modularity with nication via Ethernet munication via standard • good coordinated motion • larger web server applications
• IoT connection with MQTT support and OPC UA server PLC and a option boards based industrial fieldbus industrial fieldbus and capability on EtherCAT or • very large High Availability application with complex
• Very efficient web visualization with HTML5 support small number • less-complex communication • IoT capability with MQTT Ethernet based protocols onboard CAN Modbus TCP communication
• Safety applications with local or decentralized I/O on PROFINET/PROFIsafe of I/Os on Ethernet based industrial and OPC UA • simple safety application • medium to complex com- • highly-complex safety applications with PROFIsafe
• Fast coordinated motion capability from small to large CPU with embedded motion I/O fieldbus • building control applica- local or decentralized on munication via industrial • high speed and/or large coordinated motion control
or EtherCAT support • IoT enabled with MQTT and tions with KNX PROFIsafe fieldbus and Ethernet • very large flash disk for data collection
OPC UA • simple or coordinated • coordinated motion based protocols
• web server applications motion capability on EtherCAT or • medium safety applica-
• simple motion capability with CAN onboard tions with PROFIsafe
high-speed onboard I/Os
A500-eCo V3 AC500 V3
Basic Standard Pro
What does your project need? PM5012-x-ETH PM5032-x-ETH PM5052-xETH PM5072-x-2ETH(W) PM5630 V3 PM5650 V3 PM5670 V3 PM5675 V3
Compactness and onboard I/Os ?
Basic 230 V AC power supply onboard ?
Standard operational temperature ?
Extreme environmental conditions (e.g. high temperature, humidity or vibrations) ? - - - (W version) (XC) (XC) (XC) (XC)
Functional Safety up to SIL3 ?
Simple motion with PTO module FM562 / onboard I/O ? - / - / - / - / - / - - / - - / - - / -
Application feature Data logging ? - - - - - - - - - - - -
-
(1) (4)
High-speed motion or interpolated motion ?
(1) (4)
-
(1) (4)
-
(1) (4)
(1) (4)
-
Condition monitoring CMS ?
-
-
-
-
-
-
-
-
-
High availability with CS31 protocol ?
-
High availability with Ethernet Modbus TCP protocol ?
HTML5 web server ?
-
Telecontrol with IEC 60870-5-104 ?
-
-
-
-
-
-
-
-
Process control objects library (PCO) for DCS integration ? - - -
Application performance More than 1 Cyclic and 1 Interrupt IEC 61131 Task ?
-
4 or more IEC 61131 Tasks ?
More than 2 kB retain variables ?
8 MB / 1 MB (5)
160 MB / 32 MB (5)
1 MB / 256 kB (5) 2 MB / 512 kB (5) 4 MB / 768 kB (5)
80 MB / 8 MB (5)
8 MB / 2 MB (5)
Total user program memory / thereof user program code + data max.
160 MB / 32 MB (5)
-
Large flash disk for data collecting ?
-
8GB
-
-
Web server data ≤ 1MB ?
-
-
see above (2)
see above (2)
see above (2)
see above (2)
Web server data ≥ 4MB ?
see above (2)
see above (2)
-
see above (2)
Floating point arithmetic calculation with FPU ?
-
Number of Ethernet Sockets for parallel connection ?
50
8
120
30
20
Number of Modbus TCP Sockets (part of Ethernet Sockets) ?
20
120
30
CPU performance (ns per bit instruction) ? Unlimited (3) Unlimited (3) Unlimited (3) Unlimited (3) Unlimited (3) Unlimited (3) Unlimited (3) Unlimited (3)
20 ns
20 ns
20 ns
10 ns
20 ns
2 ns
20 ns
2 ns
Decentralized I/Os or communication on serial CS31 fieldbus ? - - - - - - - -
Decentralized I/Os or communication on serial Modbus RTU fieldbus ?
-
-
Decentralized I/Os or communication on PROFIBUS DP master / slave fieldbus ?
-
-
/ (1)
/ (1)
/ (1)
/ (1)
Communication/Fieldbus Decentralized I/Os or communication on Modbus TCP network ?
-
/ -
/ -
-
-
-
/ -
/ -
Decentralized I/Os or communication on CAN/CANopen master / slave fieldbus ?
-
-
Decentralized I/Os or communication on PROFINET IO controller / device network ?
-
-
/
/
/
/
-
-
Decentralized I/Os or communication on EtherCAT master network ?
(1) (4)
-
Two or more onboard Ethernet interfaces ?
-
-
-
(1)(4)
(1) (4)
-
(1)(4)
Onboard selectable protocols Ethernet/IP ?
(1)(4)
(1)(4)
(1)(4)
(1) (4)
(4)
-
-
(4)
KNX building communication
(4)
-
(4)
(4)
BACnet (B-ASC profile) / BACnet (B-C profile)
(4)
IEC 61850 MMS / GOOSE protocol ?
(4)
(4)
(4)
(4)
IoT enabled with MQTT with TLS secured communication, support of JSON library - - - - - - - - / (4) - / (4) - / (4) - / (4) - / (4)
OPC UA server ? -
- Not possible (1) In preparation
Possible but not optimal solution (2) Total memory for code, data and web server with AC500 V3 CPU, thereof size of User data and User program is smaller and dynamically allocated
Possible with additional devices (3) Number of ETH Socket total is basically not limited, but depends on: CPU load, priority of application tasks, kind of used protocols, amount of data transfered, network structure
(4) Feature(s) is (are) licensed, runtime license per CPU.
Possible and best selection (5) Memory size of V2 versus V3 CPUs is not comparable. Projects have a different and separate User Program code and Data memory calculation in Automation Builder 2.4.0
version or later: System, configuration and web server parts are not counted anymore. This results in typically about 50% lower memory usage compared to V2, and even
lower memory usage compared to V3 projects compiled in Automation Builder 2.3.0 or before.