Page 292 - EPR Catalog 2015
P. 292

Analog signal converters - CC-E range
Technical data

Type                                                                                                     CC-E/I                              CC-E IAC/ILPO
                                                                                                                                                    C-D
Input circuits - Analog inputs                                                                            J-G-H
Rated input range                                                                                                                   2 meas. ranges selectable
Measuring frequency                                                                          AC current          DC current   0-1 A / 0-5 A / sinusoidal
Overload capacity of inputs                                                                                                   50/60 Hz
                                                 0-5 A / 0-20 A 0-5 A / 0-20 A
Gain adjustment range                                                                                                         10 x INom (50 A) for max. 2 s
Offset adjustment range                          input range 1 10 x INom (50 A) for max. 1 s
Input impedance / resistance                                                                                                  10 x INom (200 A) for max. 2 s
Output circuits - Analog outputs                 input range 2 10 x INom (200 A) for max. 1 s                                 -
                                                                                                                              -
                                                 ±5 % (universal devices)                                                     5 m⏲
                                                                                                                               F-E passive current output in pro-
                                                 ±5 % (universal devices)

                                                 5A : 65 m⏲                                               20 A : 2.5 m⏲

                                                                                             D-F Current         A-C Voltage

                                                                                                                                 portion to input current

        Output signal                            0-20 mA /                                                0-10 V              4-20 mA
                                                 4-20 mA
4                                                                                                                             12 V DC: 150 ⏲,
        Output burden / load                     ͨ 500 ⏲                                                  ͧ 1.0 ⏲             24 V DC: 750 ⏲
                                                                                                                              30 V DC: 1050 ⏲
        Accuracy 1)                              ± 2 % of full-scale
        Offset adjustment range                  ±5 % (universal device)                                                      ±5%
        Gain adjustment range                    ±5 % (universal device)                                                      ± 20 %
        Residual ripple                          < 0.5 %

Response time                                    0.5 s                                                                        0.6 s
Transmission frequency                           DC or 50/60 Hz                                                               AC: 50/60 Hz
Reaction to input circuit interruption
                                                 Low fail safe: output voltage                                                -
                                                 < 200 mV, output current < 400 μA

Supply circuits                                  K-M DC versions                                             AC versions      12-30 V DC
Supply voltage                                          24 V DC                                           110-240 V AC        -
                                                        -15...+15 %                                       50/60 Hz
Supply voltage tolerance
                                                                                                          -15...+10 %

Power consumption                                typ 1.5 W                                                typ 1.5 VA          -
Indication of operational states                 U: green LED                                                                 -
Supply voltage

General data                                     0...+60 °C / -20...+80 °C                                                    -20...+60 °C / -40...+80 °C
Ambient temperature rangeoperation / storage     ± 500 ppm/°C                                                                 300 ppm/°C
Temperature coefficient

Degree of protection (DIN 40050)                 IP20

Mounting position                                ventilation slots on top and bottom

Mounting                                         DIN rail (IEC/EN 60715), snap-on mounting

Electrical connection

Wire size                                        rigid 0.2-4 mm² (24-12 AWG)

                                        fine-strand with(out) wire end ferrule 0.2-2.5 mm² (24-14 AWG)

Stripping length                                 7 mm (0.28 inch)

Tightening torque                                0.5 Nm (4.4 lb.in)

Electromagnetic compatibility

Interference immunity                            EN 61000-6-2

electrostatic discharge (ESD)                    IEC/EN 61000-4-2 Level 3 (±6 kV / ±8 kV)

electromagnetic field (HF radiation resistance)  IEC/EN 61000-4-3 10 V/m

fast transients (Burst)                          IEC/EN 61000-4-4 Level 3 (±2 kV / 5 kH)

powerful impulses (Surge)                        IEC/EN 61000-4-5 ±2 kV / ±1 kV

HF line emission                                 IEC/EN 61000-4-6 10 V

Interference emission                            EN 61000-6-4 Class B

Isolation data

Test voltage (between all isolated circuits)     2.5 kV AC                                                                    250 V AC
Rated insulation voltage                         -

1) Includes non-linearity and factory setting, influenced by supply voltage and output load.
Approvals see „Overview“ on page 4/3

4/13 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210