Page 370 - EPR Catalog 2015
P. 370
Logic relays
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated.
Type CL-LSR.C...12DC1 CL-LSR....12DC2 CL-LSR.C...12AC1 CL-LSR.C...12AC2
Input circuit - Digital inputs 12 V DC CL-LST.C...12DC2 24 V AC 115 / 230 V AC
24 V DC -
Number 8
Inputs can be used as analog inputs 2 (I7, I8)
Indication of operational states LCD-Display (if existing)
Electrical isolation from voltage supply no
between digital inputs no
from the outputs yes
Rated operational 12 V DC 24 V DC 24 V AC
0-6 V AC (sinusoidal)
voltage Ue Ue on „0“ signal 4 V DC (I1-I8) < 5 V DC (I1-I8) 0-40 V AC (sinusoidal)
Ue on „1“ signal 8 V DC (I1-I8) > 15 V DC (I1-I6), > 9.5 V DC, 79-264 V AC
> 8 V DC (I7, I8)
14-26.4 V AC (sinusoidal)
(sinusoidal) (I1-I6),
> 7 V AC (sinusoidal)
(I7,I8)
Rated frequency - 50-60 Hz
Input current 3.3 mA (at 12 V DC,
on „1“ signal I1-I6), 3.3 mA (at 24 V DC, 4 mA 6x0.25 mA
1.1 mA (at 12 V DC, I6-I7),
6 I7, I8) 2.2 mA (at 24 V DC, (at 24 V AC, 50 Hz, I1-I6), (at 115 V AC, 60 Hz,
I7, I8)
2 mA I1-I6),
(at 24 V AC, 50 Hz, I7,I8), 6x0.5 mA
2 mA (at 24 V DC, I7, I8) (at 230 V AC, 50 Hz,
I1-I6)
2x4 mA
(at 115 V AC, 60 Hz,
I7, I8),
2x6 mA
(at 230 V AC, 50 Hz,
I7, I8)
Time delay debounce ON 20 ms 80 ms (at 50 Hz), 66 2/3 ms (at 60 Hz)
from „0“ to „1“ debounce OFF typ. 0.3 ms (I1-I6),
typ. 0,25 ms (I1-I8) 20 ms (at 50 Hz), 16 2/3 ms (at 60 Hz)
Time delay typ. 0.35 ms (I7, I8)
from „1“ to „0“ debounce ON 20 ms 80 ms (at 50 Hz), 80 ms (at 50 Hz, I1-I6),
66 2/3 ms (at 60 Hz) 66 2/3 ms (at 60 Hz,
debounce OFF typ. 0.3 ms (I1-I6), - I1-I6)
typ. 0.15 ms (I7, I8) 20 ms (at 50 Hz), 160 ms (at 50 Hz, I7, I8),
16 2/3 ms (at 60 Hz) 150 ms (at 60 Hz, I7, I8)
Cable length (unshielded) 100 m 20 ms (at 50 Hz, I1-I6),
Maximum cable length per input - - 16 2/3 ms (at 60 Hz,
40 m I1-I6)
Frequency counter Number 2 (I3, I4) 100 ms (at 50 Hz, I7. I8),
- 100 ms (at 60 Hz, I7, I8)
counting frequency < 1 kHz - -
- 40 m (I1-I6),
pulse shape square-wave - 100 m (I7, I8)
- -
pulse / pause ratio 1:1 - -
- -
Rapid counter inputs Number 2 (I1, I2) - -
- -
counting frequency < 1 kHz -
-
pulse shape square-wave -
-
pulse / pause ratio 1:1
Cable length (shielded) < 20 m
Input circuit - Analog inputs
Number 2 (I7, I8) -
Electrical isolation from voltage supply no -
from the digital inputs no -
Input type -
Signal range from the outputs yes -
Resolution from PC interface, no
-
Input impedance memory -
Accuracy of the module, CL-NET, -
actual value -
Conversion time CL-LINK -
analog/digital DC voltage -
Input current 0-10 V DC -
Cable length (shielded) -
analog 0.01 V -
digital 0.01 V; 10 Bit (value 1-1023) -
-
11.2 k⏲
two CL devices ±3 %
within one device ±2 %, ±0.12 V
Input delay ON 20 ms
Input delay OFF each cycle
< 1 mA
< 30 m
6/11 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C02010