Page 60 - EPR Catalog 2015
P. 60

CT-S range
Connection diagrams

CT-MVS.21                                 CT-MVS.22                            CT-MVS.23                                                                             CT-MVS.12

1 A1 15 25 21                                                                                                                                                           A1 15 Y1/B1
                                                                                                                                                                           Y1/
                                                                                                                                                                           B1 A1 15
Y1/B1 Z2   Z1            2CDC 252 002 F0b06 A1   15    25                        A1   15    25
                                                                                     2CDC 252 003 F0b06Y1/B11525Y1/B11525
Y1/        25                                                                                                                                    2CDC 252 003 F0b06Y1/Y1/
B1 A1 15                                                                                                                                                                                                      2CDC 252 004 F0b06B1 A1B1 A1
            21

    A2 16 18 26 28                            A2 16 18 26 28                       A2 16 18 26 28                                                                              A2 16 18

                                   22 24     28 26                                28 26                                                                                 18 16 A2
                                             18 16 A2                             18 16 A2
 28 24 26 22                                                                                                                                                         A1-A2 Supply: 24-48 V DC
   18 16 A2                               A1-A2 Supply: 224-48 V DC            A1-A2 Supply: 380-440V AC                                                                           or 24-240 V AC
                                                        or 24-240 V AC         A1-Y1/B1 Control input
A1-A2 Supply: 24-240 V AC/DC                                                   15-16/18 1. c/o contact                                                               A1-Y1/B1 Control input
A1-Y1/B1 Control input                    A1-Y1/B1 Control input               25-26/28 2. c/o contact                                                               15-16/18 1. c/o contact
15-16/18 1. c/o contact                   15-16/18 1. c/o contact
25-26/28 2. c/o contact                   25-26/28 2. c/o contact
21-22/24 2. c/o contact as

              instantaneous contact

Z1-Z2 Remote potentiometer
              connection

CT-MXS.22                                 CT-MFS.21                            CT-MBS.22                                                                             CT-WBS.22

                                                                                                                                                                        A1 15 25
  A1   15  25            2CDC 252 005 F0b06A1 15 25 21                         A1 15 25 21
  Z3   Z2  Z1                                                                        2CDC 252 006 F0b06X1 Z2 Z1Z2 Z1
Y1/                                                                                                                                              2CDC 252 007 F0b06
B1 A1  15   25                                                                                                                                                                                                2CDC 252 008 F0b06A1 1525A1 1525A1 1525

                                                        21                                     21

 A2 16 18 26 28                            A2 16 18    26 28                    A2 16 18    26 28                                                                      A2 16 18 26 28

28 26 Y1/B1                               28 24 26 22   22 24                  28 24 26 22   22 24                                                                      28 26
18 16 A2                                   18 16                                18 16                                                                                   18 16 A2
                                                          Y1                                   Y1
                                                          A2                                   A2                                                                    A1-A2 Supply: 24-48 V DC
                                                                                                                                                                                   or 24-240 V AC
A1-A2 Supply: 24-48 V DC                  A1-A2 Supply: 24-240 V AC/DC         A1-A2 Supply: 24-48 V DC
              or 24-240 V AC                                                                 or 24-240 V AC                                                          15-16/18 1. c/o contact
                                          15-16/18 1. c/o contact                                                                                                    25-26/28 2. c/o contact
A1-Y1/B1 Control input                                                         15-16/18 1. c/o contact
                                          25-26/28 2. c/o contact
15-16/18 1. c/o contact                                                        25-26/28 2. c/o contact
                                          21-22/24 2. c/o contact as
25-26/28 2. c/o contact                                 instantaneous contact  21-22/24 2. c/o contact as
                                                                                             instantaneous
Z1-Z2  Remote                             Y1-Z2  Control input                               contact
Z3-Z2  potentiometer                      X1-Z2
       connection                         Z1-Z2  Control input                 Y1-Z2 Control input

       Remote                                    Remote potentiometer          Z1-Z2  Remote
       potentiometer                             connection                           potentiometer
       connection                                                                     connection

A CT-ERS.21                               A CT-ERS.22                          A CT-ERS.12

   A1 15 25                                  A1 15 25                             A1 15

                                                                                       A1 15
A1 15      25            2CDC 252 009 F0b06A1 15       25
                                                                                     2CDC 252 009 F0b06
                                                                                                                                                 2CDC 252 010 F0b06
A2 16 18 26 28                            A2 16 18 26 28                              A2 16 18

28 26                                     28 26                                   18 16 A2
18 16 A2                                  18 16 A2
                                                                               A1-A2 Supply: 24-48 V DC
A1-A2 Supply: 24-240 V AC/DC              A1-A2 Supply: 24-48 V DC                           or 24-240 V AC
                                                        or 24-240 V AC
15-16/18 1. c/o contact                                                        15-16/18 1. c/o contact
25-26/28 2. c/o contact                   15-16/18 1. c/o contact

                                          25-26/28 2. c/o contact

1/49 ABB | Catalog Electronic Products and Relays 2015 | 2CDC 110 004 C0210
   55   56   57   58   59   60   61   62   63   64   65