Page 61 - EPR Catalog 2015
P. 61

CT-S range
Connection diagrams

B CT-APS.21                   B CT-APS.22                   B CT-APS.12                   B CT-AHS.22

                                                               A1 15 Y1/B1                   A1 15 25                                                                                                                   1
                                                                                                         Z2

                                                                                             A1 15 25
  A1   15  25   2CDC 252 011 F0b06A1 15  25                 Y1/    15
Y1/B1  15   25                                                             2CDC 252 011 F0b06Y1/B11525B1 A1
Y1/                                                                                                                                     2CDC 252 012 F0b06Y1/
B1 A1                                                                                                                                                                                               2CDC 252 013 F0b06B1 A1

      A2 16 18 26 28                A2 16 18 26 28                    A2 16 18            A2 16 18 26 28

   28 26                         28 26                         18 16 A2                   28 26 Y1
   18 16 A2                      18 16 A2                                                 18 16 A2
                                                            A1-A2 Supply: 24-48 V DC or
A1-A2 Supply: 24-240 V AC/DC  A1-A2 Supply: 24-48 V DC or                 24-240 V AC     A1-A2  Supply: 24-48 V DC or
A1-Y1/B1 Control input                      24-240 V AC                                   Y1-Z2  24-240 V AC
15-16/18 1. c/o contact                                     A1-Y1/B1 Control input
25-26/28 2. c/o contact       A1-Y1/B1 Control input        15-16/18 1. c/o contact              Control input
                              15-16/18 1. c/o contact
                              25-26/28 2. c/o contact                                     15-16/18 1. c/o contact

                                                                                          25-26/28 2. c/o contact

B CT-ARS.11                   B CT-ARS.21                   F CT-SDS.22                   F CT-SDS.23

   A1 15                         A1 15 25                      A1 17                         A1 17

        A1 15                    A1 15 25                           A1 17                         A1 17
                2CDC 252 014 F0b06
    A2 16 18                                                               2CDC 252 015 F0b06
18 16 A2                                                                                                                                2CDC 252 016 F0b06
                                                                                                                                                                                                    2CDC 252 016 F0b06
                              A2 16 18 26 28                    A2 18 28                      A2 18 28
                                                            18 28 A2                      18 28 A2
                              28 26
                              18 16 A2

A1-A2 Supply: 24-240 V AC/DC  A1-A2 Supply: 24-240 V AC/DC  A1-A2  Supply: 24-48 V DC or  A1-A2  Supply: 380-440 V AC
15-16/18 1. c/o contact       15-16/18 1. c/o contact              24-240 V AC            17-18  1. n/o contact
                              25-26/28 2. c/o contact       17-18  1. n/o contact         17-28  2. n/o contact
                                                            17-28
                                                                   2. n/o contact

                                                           2CDC 110 004 C0210 | Catalog Electronic Products and Relays 2015 | ABB 1/50
   56   57   58   59   60   61   62   63   64   65   66