Page 88 - PLC Automation
P. 88
86 MAIN CATALOG PLC AUTOMATION
—
AC500-eCo
Technical data
AC500-eCo V3 CPUs
Type PM5012-T-ETH PM5012-R-ETH PM5032-T-ETH PM5032-R-ETH PM5052-T-ETH PM5052-R-ETH PM5072-T-2ETH PM5072-T-2ETHW(2)
Relay - 4 - 6 - 6 - -
Functionality - Standard - Standard - Standard - -
output output output
Rated voltage 24 V DC 230 V AC 24 V DC 230 V AC 24 V DC 230 V AC 24 V DC 24 V DC
Nominal current per channel 0.5 A 2 A 0.5 A 2 A 0.5 A 2 A 0.5 A 0.5 A resistive
03
resistive resistive resistive resistive resistive resistive resistive
Onboard digital input /output configurable channels
Channels - - 2 digital in/output configurable
As digital input used - - up to 2
Signal voltage - - 24 V DC
Functionality - - Standard input
As digital output transistor used - - up to 2 up to 2 up to 2 up to 2 up to 2
standard standard standard standard standard
or or
PTO with pulse signal and direction - - - up to 1 - up to 1 -
(200 kHz) (200 kHz)
PTO with CC/CCW pulse outputs - - - up to 1 - up to 1 -
(200 kHz) (200 kHz)
PWM - - - up to 2 - up to 2 -
(30 kHz) (30 kHz)
Limit switch - - - up to 2 - up to 2 -
Rated voltage - - 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC
Nominal current per channel - - 0.5 A 0.5 A 0.5 A 0.5 A 0.5 A 0.5 A resistive
resistive resistive resistive resistive resistive
Max. number of centralized
inputs/outputs
Max. number of extension modules on - up to max. 10 (S500 and/or S500-eCo I/O modules allowed)
I/O bus
Digital inputs only onboard 6 + 320 + 12 + max. 2DC as 320 + 12 + max. 2DC as 2DI + option boards
1 option board 2DI + opt. boards
( Max. 128 Byte Var.)
outputs only onboard 4 + 320 + 8/6 + max. 2DC 320 + 8/6 + max. 2DC as 2DO + option boards
1 option board as 2DO + opt. boards
( Max. 128 Byte Var.)
Analog inputs only 1 option board max. 64 including 160 + option boards
option boards
( Max. 128 Byte Var.)
outputs only 1 option board max. 64 including 160 + option boards
option boards
( Max. 128 Byte Var.)
Max. number of decentralized depends on the used standard fieldbus (1)
inputs/outputs
Option board slots for extension Each slot can be used for all type of existing option boards, same option board for serial interface or
digital/analog I/O extension can be used on several slots per CPU
Max. number of option board slots max. 1 2 3
Type of option board
KNX communication address switch - TA5130-KNXPB only on
1 slot
Real-time clock (with Goldcap TA5131-RTC -
back-up)
Serial interface TA5141-RS232I, TA5142-RS485/TA5142-RS485I
Digital in/output channels TA5101-4DI, TA5105-4DOT, TA5110-2DI2DOT
Analog in/output channels (1) TA5120-2AI-UI, TA5122-2AI-TC, TA5123-2AI-RTD, TA5126-2AO-UI
(1) In preparation